How this calculator works
Off-grid systems have no grid to fall back on, so they are sized for the worst month, not the average. The panel array must refill a day's use in the darkest month; the battery must carry you through cloudy days; and the charge controller must handle the current from the panels into the battery.
Higher system voltages carry the same power with lower current, which means thinner cables and smaller controllers. That is why larger systems use 48 V.
Formula
Panel array (W) = daily Wh ÷ (worst-month peak sun hours × derate) Battery (Wh) = daily Wh × days ÷ (depth of discharge × inverter efficiency) Battery (Ah) = battery Wh ÷ system voltage Charge controller (A) ≈ panel W ÷ system voltage × 1.25
Assumptions and limits
- The 1.25 factor is a common safety margin on PV current; the charge controller maker's maximum PV voltage and current must also be respected.
- Educational sizing only. It is not an electrical design and does not check cables, fuses, earthing or local codes.
Worked example
1.5 kWh a day at 24 V. 1,500 Wh ÷ (4 h × 0.75) = 500 W of panels, so 2 × 400 W = 800 W. Battery: 1,500 × 2 days ÷ (0.9 × 0.92) ≈ 3,620 Wh ≈ 151 Ah at 24 V. Controller: 800 ÷ 24 × 1.25 ≈ 42 A.
Questions
12 V, 24 V or 48 V?
This is an estimate for information only. It is not a quote, a site survey or an electrical design. Ask a qualified installer before you buy or wire anything.