Compare

LONGi LR5-54HTH-440M vs Trina Solar TSM-440NEG9R.28

Datasheet values side by side. Every number comes from the manufacturer's own datasheet or manual, linked under each product. Where we could not record a value from the sheet, we say so instead of filling it in.

Manufacturer data onlyNo paid placements

Outlines are our own drawings, to the same scale from the datasheet dimensions. They are not product photos.

Specifications

SpecLR5-54HTH-440MTSM-440NEG9R.28
Power and efficiency
Maximum power (Pmax) 440 W 440 W
Module efficiencyhigher is better 22.5 % better 22 %
Electrical (STC)
Voltage at max power (Vmp) 33.24 V 44 V
Current at max power (Imp) 13.24 A 10.01 A
Open-circuit voltage (Voc) 39.53 V 52.2 V
Short-circuit current (Isc) 14.3 A 10.67 A
Maximum system voltagehigher is better 1,500 V 1,500 V
Maximum series fuse 25 A 25 A
Heat behaviour
Pmax temperature coefficienthigher is better -0.29 %/°C -0.29 %/°C
Voc temperature coefficienthigher is better -0.23 %/°C better -0.24 %/°C
Isc temperature coefficient 0.05 %/°C 0.04 %/°C
Size and build
Length 1,722 mm 1,762 mm
Width 1,134 mm 1,134 mm
Depth 30 mm 30 mm
Weight 20.8 kg 21 kg
Cells 108 144
Other datasheet values
Operating temperatureNot recorded: see the datasheet-40 to +70 °C
Warranty and notes
Warranty15 years materials and processing; 25 years power output. First-year degradation under 1.5 %.15-year product warranty; 30-year power guarantee (1 % loss in year one, then 0.4 % a year).
Notes on the sourceSTC values (1000 W/m², 25 °C, AM1.5). Pmax tolerance stated as ±3 %.The PDF text came out without column labels, so two checks were used: Vmp × Imp = 44.00 × 10.01 = 440 W (STC row, not NOCT), and 440 W ÷ (1.762 m × 1.134 m) = 22.0 % efficiency. Temperature coefficients are read in the order the sheet lists them (Pmax, Voc, Isc). Check the PDF before relying on them.
DatasheetManufacturer source
checked 2026-11-25
Manufacturer source
checked 2026-11-25

"Better" only marks lines where a higher or lower number is clearly an advantage. Power, size and voltage are design choices, so they are not marked. A product can be better on paper and still be the wrong choice for your roof or system.

How they work with other equipment

Calculated from the datasheets with the same rules as the Planner's inverter check. Change the temperatures for your place.

°C