Specifications

SpecPrimo GEN24 5.0SB5.0-1AV-41
Output
Rated AC power 5,000 W 5,000 W
Maximum apparent power 5,000 VA 5,000 VA
Maximum output current 27.5 A 22.8 A
Grid 1~ NPE 220 / 230 V, 50 / 60 Hz 220 / 230 / 240 V, 50 / 60 Hz
PV input
Maximum PV array powerhigher is better 7,500 Wp 7,500 Wp
Maximum DC input voltagehigher is better 600 V 600 V
MPP voltage range 230 – 530 V (usable 65 – 530 V) 175 – 500 V
Minimum input voltagelower is better 65 V better 100 V
Start voltagelower is better 80 V better 125 V
Rated input voltage 400 V 365 V
MPP trackershigher is better 2 2
Strings per tracker 2 + 2 DC connections 2
Maximum input current per tracker 22 A / 12 A 15 A / 15 A
Maximum short-circuit current per tracker 41.25 A / 22 A 20 A / 20 A
Efficiency
Maximum efficiencyhigher is better 97.6 % better 97 %
European efficiencyhigher is better Not recorded: see the datasheet 96.5 %
European efficiency 96.3 / 97.2 / 96.7 % (at 230 / 400 / 530 V DC) Not recorded: see the datasheet
Size
Weight 15.38 kg 17.5 kg
Height 530 mm 470 mm
Width 474 mm 435 mm
Depth 165 mm 176 mm
Warranty and notes
WarrantyNot stated in the source we usedNot stated in the source we used
Notes on the source230 – 530 V is the MPP range for full power; the inverter works from 65 V. Tracker 1 takes more current than tracker 2. Strings per tracker is read from "Number of DC connections 2+2".Values from the 5.0 column. Maximum short-circuit current per IEC 62109-2. SMA notes that under VDE-AR-N 4105 (Germany) the rated power of this model is 4,600 W.
DatasheetManufacturer source
checked 2026-11-25
Manufacturer source
checked 2026-11-25

"Better" only marks lines where a higher or lower number is clearly an advantage. Power, size and voltage are design choices, so they are not marked. A product can be better on paper and still be the wrong choice for your roof or system.